Standard: EN 12350-12
To determine the flowability, i.e. the flow time and the capability of the self compacting concrete to pass through obstacles.
The set consists of the following parts:
J-Ring Apparatus, galvanized steel made, having rectangular section 30x15 mm and median diameter of 300 mm.
The median circumference of the ring is drilled, and n. 16 cylindrical bars Ø 18x140 mm are fixed into the holes.
The bars have a close distance of 41 mm between them, to simulate a condition of higher density of the reinforced bars.
Slump Cone, galvanized steel, conforming to EN 12350-2 Spec.
Plate, galvanized steel made, dimensions 900x900 mm, with engraved two circles having 210 and 500 mm diameter and central X cross.